Where can I confirm this?
Reports and contact
- 2024 Springville City Water Quality ReportReport year: 2024Open report ↗
Provider phone: 801-491-2780
Utah · Public water system UTAH25005
Review this provider’s public water records. Confirm the name and provider ID on your bill before applying these results to your home.
Plain-language summary
SPRINGVILLE CITY is listed as a community water system in Utah County. The newest annual report year listed here is 2024. This page includes 323 provider-specific measurement records; use the stated year and units when reading each result.
Available measurements include Total Coliform Bacteria, Fecal coliform and E. coli, Turbidity for Ground Water, Arsenic. Their report and sample years appear with each result.
Public-system records do not describe every faucet. Your home’s plumbing can affect water at the tap, and regulatory records may lag local notices.
What do the available sources measure?
A detection is not automatically a violation. Compare the original value and unit with the applicable standard and the report’s compliance text.
Published by Springville City in June 2025.
| Contaminant or characteristic | Sample period | Reported result or range | Unit | Limit supplied by source | Source compliance statement |
|---|---|---|---|---|---|
| Total Coliform BacteriaMicrobiological | 2024 | ND | N/A | Presence in 5% of monthly samples | The source report did not identify this measurement as a violation. |
| Fecal coliform and E. coliMicrobiological | 2024 | ND | N/A | Conditional presence standard | The source report did not identify this measurement as a violation. |
| Turbidity for Ground WaterPhysical | 2024 | 0.3 | NTU | 5 | The source report did not identify this measurement as a violation. |
| ArsenicInorganic | 2024 | ND–1 | ppb | 10 | The source report did not identify this measurement as a violation. |
| BariumInorganic | 2024 | 0.02–0.1 | ppm | 2 | The source report did not identify this measurement as a violation. |
| Copper (tap)Lead and Copper Rule | 2023 | 0.086 (90th percentile); 0 sites over AL | ppm | AL 1.3 | The source report did not identify this measurement as a violation. |
| CyanideInorganic | 2024 | ND–10 | ppb | 200 | The source report did not identify this measurement as a violation. |
| FluorideInorganic | 2024 | ND–143 | ppb | 4000 | The source report did not identify this measurement as a violation. |
| Lead (tap)Lead and Copper Rule | 2023 | 1 (90th percentile); 0 sites over AL | ppb | AL 15 | The source report did not identify this measurement as a violation. |
| Nitrate (as Nitrogen)Inorganic | 2024 | ND–1 | ppm | 10 | The source report did not identify this measurement as a violation. |
| SeleniumInorganic | 2024 | ND–2 | ppb | 50 | The source report did not identify this measurement as a violation. |
| SodiumInorganic | 2024 | 3–38 | ppm | None set by EPA | The source report did not identify this measurement as a violation. |
| SulfateInorganic | 2024 | 9–122 | ppm | 1000 | The source report did not identify this measurement as a violation. |
| Total Dissolved SolidsInorganic | 2024 | 240–476 | ppm | 2000 | The source report did not identify this measurement as a violation. |
| Total TrihalomethanesDisinfection Byproducts | 2024 | ND–0.6 | ppb | 80 | The source report did not identify this measurement as a violation. |
| Alpha emittersRadioactive | 2024 | ND–7 | pCi/L | 15 | The source report did not identify this measurement as a violation. |
| Combined RadiumRadioactive | 2024 | 0.4–1 | pCi/L | 5 | The source report did not identify this measurement as a violation. |
| Radium 226Radioactive | 2024 | 0.36 | pCi/L | 5 | The source report did not identify this measurement as a violation. |
| Radium 228Radioactive | 2024 | ND–1 | pCi/L | 5 | The source report did not identify this measurement as a violation. |
| LithiumUCMR | 2024 | 9–21 | µg/L | Unregulated | The source report did not provide a yes/no violation determination. |
| Contaminant or characteristic | Sample period | Reported result or range | Unit | Limit supplied by source | Source compliance statement |
|---|---|---|---|---|---|
| 11Cl-PF3OUdSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoringBartholomew - Hobble Spring · Sample Tap (pre-chlorination)Source stream: 00001/WS001 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoring400 South Well NO. 2 · Sample Tap (pre-chlorination)Source stream: 00014/WS014 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoringUpper Spring Creek Spring · Sample Tap (pre-chlorination)Source stream: 90001/WS002 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoring200 N 800 E Well · Sample Tap (pre-chlorination)Source stream: 90002/WS004 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoring400 S Well · Sample Tap (pre-chlorination)Source stream: 90003/WS005 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoring900 S 1000 E Well · Sample Tap (pre-chlorination)Source stream: 90004/WS008 | 2025Collected: 2025-04-08 | 13Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoringKonold · Sample Tap (pre-chlorination)Source stream: 90005/WS009 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoring1000 S. 600 E. Well · Sample Tap (pre-chlorination)Source stream: 90006/WS006 | 2025Collected: 2025-04-08 | 22Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoringEvergreen Well · Sample Tap (pre-chlorination)Source stream: 90011/WS011 | 2025Collected: 2025-04-08 | 17Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 11Cl-PF3OUdSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 4:2 FTSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 6:2 FTSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 8:2 FTSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| 9Cl-PF3ONSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| ADONAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| HFPO-DAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NEtFOSAAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NFDHAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.02Reporting limit: 0.02 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| NMeFOSAAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.006Reporting limit: 0.006 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.005Reporting limit: 0.005 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFBSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFDoAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFEESAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHpSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFHxSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMBAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFMPAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFNAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFOSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.003Reporting limit: 0.003 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFPeSUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.004Reporting limit: 0.004 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.008Reporting limit: 0.008 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFTrDAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.007Reporting limit: 0.007 µg/LMethod: EPA 537.1Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| PFUnAUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <0.002Reporting limit: 0.002 µg/LMethod: EPA 533Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
| lithiumUCMR 5 monitoringCanyon Road Well · Sample Tap (pre-chlorination)Source stream: 90012/WS012 | 2025Collected: 2025-04-08 | <9Reporting limit: 9 µg/LMethod: EPA 200.7Individual sample result at the named facility and sample point. A < result is below the UCMR minimum reporting level (MRL), not zero. The MRL is an analytical reporting threshold, not a drinking-water limit. | µg/L | Not supplied | UCMR monitoring results are not a regulatory compliance determination. |
These are 90th-percentile monitoring summaries for the stated reporting periods. Individual sample dates are not supplied. A reported zero is retained as published; it does not establish that lead or copper is absent at an individual faucet.
| Contaminant or characteristic | Sample period | Reported result or range | Unit | Limit supplied by source | Source compliance statement |
|---|---|---|---|---|---|
| Lead (90th percentile)Lead and Copper Rule monitoring · 90th percentileSource stream: monitoring-period/2023-01-01/2025-12-31 | 2023-01-01 to 2025-12-31 (reporting period) | 0.0011System-level 90th percentile of tap samples for the stated monitoring period. The period boundaries are reporting windows, not individual sample dates. A missing result-sign code is retained as unspecified; a zero is not relabeled as a non-detection. Individual household lead or copper concentrations can differ. | mg/L | Not supplied | A monitoring-period 90th percentile is not a compliance determination or a measurement of an individual household's water. |
These are annual monitoring averages, not individual sample results or compliance determinations. A reported zero does not establish that every sample was below detection. Sampling years are shown separately from the date this site retrieved the data.
Historical annual means from Utah public monitoring records. Latest published years vary by contaminant and provider; seasonal and emergency sources are excluded. Sampling frequency and within-system variability differ. These averages cannot establish an individual tap result, detection status, or current compliance.
| Contaminant or characteristic | Sample period | Reported result or range | Unit | Limit supplied by source | Source compliance statement |
|---|---|---|---|---|---|
| Haloacetic Acids Five (HAA5)Historical annual monitoring average · Annual mean | 2023 | 42.40 | µg/L | Not supplied | This annual-mean dataset does not determine compliance. |
| Total Trihalomethanes (TTHM)Historical annual monitoring average · Annual mean | 2023 | 67.80 | µg/L | Not supplied | This annual-mean dataset does not determine compliance. |
What violation records are reported?
Health-based, treatment, monitoring, and reporting records have different meanings. Resolution status and source dates remain visible.
| Period | Contaminant / rule | Category | Status | Resolution |
|---|---|---|---|---|
| Not available to September 3, 2016 | Groundwater Rule0700 | Health Based | Resolved | September 3, 2016 |
| Not available to September 3, 2016 | Groundwater Rule0700 | Health Based | Resolved | September 3, 2016 |
| Not available to Not available | Revised Total Coliform Rule8000 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2025 to Not available | Consumer Confidence Rule7000 | Monitoring Or Reporting | Resolved | Not available |
| February 10, 2024 to February 10, 2024 | Consumer Confidence Rule7000 | Monitoring Or Reporting | Resolved | February 10, 2024 |
| January 7, 2024 to February 10, 2024 | Consumer Confidence Rule7000 | Monitoring Or Reporting | Resolved | February 10, 2024 |
| January 3, 2017 to Not available | Surface Water Treatment Rule0200 | Monitoring Or Reporting | Resolved | Not available |
| January 2, 2017 to Not available | Surface Water Treatment Rule0200 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2017 to Not available | Surface Water Treatment Rule0200 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2015 to Not available | Consumer Confidence Rule7000 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2013 to Not available | Lead and Copper Rule5000 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2011 to Not available | Lead and Copper Rule5000 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Dalapon2031 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Total Polychlorinated Biphenyls (PCB)2383 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Pentachlorophenol2326 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | HEXACHLOROBENZENE2274 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | 2,4-D2105 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | LASSO2051 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Atrazine2050 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Dinoseb2041 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Picloram2040 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Simazine2037 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | OXAMYL2036 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | BHC-GAMMA2010 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Di(2-ethylhexyl) adipate2035 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Toxaphene2020 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Carbofuran2046 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Di(2-ethylhexyl) phthalate2039 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Hexachlorocyclopentadiene2042 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Benzo(a)pyrene2306 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Chlordane2959 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Heptachlor2065 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | 2,4,5-TP2110 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Methoxychlor2015 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Heptachlor epoxide2067 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2009 to Not available | Endrin2005 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Heptachlor2065 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Endrin2005 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Toxaphene2020 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | OXAMYL2036 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Simazine2037 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Di(2-ethylhexyl) phthalate2039 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Picloram2040 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Dinoseb2041 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Hexachlorocyclopentadiene2042 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Carbofuran2046 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Atrazine2050 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | 2,4-D2105 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | 2,4,5-TP2110 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | HEXACHLOROBENZENE2274 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Benzo(a)pyrene2306 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Pentachlorophenol2326 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Total Polychlorinated Biphenyls (PCB)2383 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Methoxychlor2015 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Chlordane2959 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | BHC-GAMMA2010 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Di(2-ethylhexyl) adipate2035 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Dalapon2031 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | LASSO2051 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2008 to Not available | Heptachlor epoxide2067 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Picloram2040 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Atrazine2050 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | LASSO2051 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Heptachlor2065 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | 2,4-D2105 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Carbofuran2046 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Total Polychlorinated Biphenyls (PCB)2383 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Di(2-ethylhexyl) adipate2035 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Chlordane2959 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | OXAMYL2036 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | BHC-GAMMA2010 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Heptachlor epoxide2067 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Simazine2037 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Toxaphene2020 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Methoxychlor2015 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | 2,4,5-TP2110 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Dinoseb2041 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Pentachlorophenol2326 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Benzo(a)pyrene2306 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Endrin2005 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Di(2-ethylhexyl) phthalate2039 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Dalapon2031 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | Hexachlorocyclopentadiene2042 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2008 to Not available | HEXACHLOROBENZENE2274 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2008 to Not available | Combined Uranium4006 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2008 to Not available | Radium-2284030 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2008 to Not available | Gross Alpha, Excl. Radon and U4000 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2008 to Not available | Combined Radium (-226 and -228)4010 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2008 to Not available | Radium-2264020 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2007 to Not available | Gross Alpha, Excl. Radon and U4000 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2007 to Not available | Radium-2264020 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2007 to Not available | Combined Uranium4006 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2007 to Not available | Combined Radium (-226 and -228)4010 | Monitoring Or Reporting | Resolved | Not available |
| January 10, 2007 to Not available | Radium-2284030 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2007 to Not available | Gross Alpha, Excl. Radon and U4000 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2007 to Not available | Combined Radium (-226 and -228)4010 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2007 to Not available | Radium-2264020 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2007 to Not available | Radium-2284030 | Monitoring Or Reporting | Resolved | Not available |
| January 7, 2007 to Not available | Combined Uranium4006 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2007 to Not available | Radium-2264020 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2007 to Not available | Gross Alpha, Excl. Radon and U4000 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2007 to Not available | Radium-2284030 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2007 to Not available | Combined Radium (-226 and -228)4010 | Monitoring Or Reporting | Resolved | Not available |
| January 4, 2007 to Not available | Combined Uranium4006 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2,4-Trichlorobenzene2378 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Benzene2990 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1-Dichloroethylene2977 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | CHLOROBENZENE2989 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Styrene2996 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | p-Dichlorobenzene2969 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Vinyl chloride2976 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Styrene2996 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Ethylbenzene2992 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Tetrachloroethylene2987 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | trans-1,2-Dichloroethylene2979 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2,4-Trichlorobenzene2378 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | o-Dichlorobenzene2968 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1,1-Trichloroethane2981 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | cis-1,2-Dichloroethylene2380 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Trichloroethylene2984 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | DICHLOROMETHANE2964 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | trans-1,2-Dichloroethylene2979 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Trichloroethylene2984 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Carbon tetrachloride2982 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Toluene2991 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Xylenes, Total2955 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Ethylbenzene2992 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | p-Dichlorobenzene2969 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Tetrachloroethylene2987 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2-Dichloropropane2983 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Vinyl chloride2976 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | DICHLOROMETHANE2964 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2-Dichloroethane2980 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Benzene2990 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1,2-Trichloroethane2985 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Xylenes, Total2955 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2-Dichloropropane2983 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | o-Dichlorobenzene2968 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1-Dichloroethylene2977 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,2-Dichloroethane2980 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1,1-Trichloroethane2981 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Carbon tetrachloride2982 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | cis-1,2-Dichloroethylene2380 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | CHLOROBENZENE2989 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | Toluene2991 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2007 to Not available | 1,1,2-Trichloroethane2985 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Methoxychlor2015 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | OXAMYL2036 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Di(2-ethylhexyl) phthalate2039 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Dinoseb2041 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Endrin2005 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Di(2-ethylhexyl) adipate2035 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Toxaphene2020 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Pentachlorophenol2326 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Dalapon2031 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Chlordane2959 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Heptachlor epoxide2067 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Simazine2037 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Benzo(a)pyrene2306 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | HEXACHLOROBENZENE2274 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Total Polychlorinated Biphenyls (PCB)2383 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | 2,4-D2105 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Heptachlor2065 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Atrazine2050 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | LASSO2051 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Carbofuran2046 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | 2,4,5-TP2110 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | BHC-GAMMA2010 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Hexachlorocyclopentadiene2042 | Monitoring Or Reporting | Resolved | Not available |
| January 1, 2006 to Not available | Picloram2040 | Monitoring Or Reporting | Resolved | Not available |
| January 8, 2002 to Not available | Coliform (TCR)3100 | Health Based | Resolved | Not available |
| January 6, 1998 to Not available | Coliform (TCR)3100 | Monitoring Or Reporting | Archived | Not available |
| January 6, 1998 to Not available | Coliform (TCR)3100 | Monitoring Or Reporting | Archived | Not available |
| January 5, 1998 to Not available | Coliform (TCR)3100 | Monitoring Or Reporting | Archived | Not available |
| January 5, 1998 to Not available | Coliform (TCR)3100 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1993 to Not available | Nitrite1041 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Selenium1045 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Arsenic1005 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Chromium1020 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Nitrate-Nitrite1038 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Mercury1035 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Barium1010 | Monitoring Or Reporting | Archived | Not available |
| January 1, 1989 to Not available | Cadmium1015 | Monitoring Or Reporting | Archived | Not available |
Where can I confirm this?
Provider phone: 801-491-2780
How fresh are the sources?
Compare reported values, limits, and sampling periods.
Confirm the matchUse an address, then confirm with your bill or utility.
Keep learningUnderstand testing, treatment, and the limits of public records.